Portable Smart Refrigerated Calibration Bath

DTS-EM95BG Compact Smart Refrigerated Calibration Bath with Elec. Meas.

2026-10-13 This article is read 185 Times

EM Portable Bath-95.jpg

◇ Introduction ◇ Function◇ Parameter◇ Product order◇ Download◇ Related products

Introduction

DTS-EMBG Series Compact Smart Refrigerated Calibration Bath with Elec. Meas. deeply integrated with a high precision electrical measurement module, the device is furnished with an independent standard channel and multiple channels under test. It is compatible with thermocouples, thermal resistors, temperature transmitters, temperature switches and other devices. It can simultaneously acquire thermal field and measured data, display various test parameters in real time, and automatically judge whether the tested instruments are qualified. It supports full life cycle management of sensors and can generate standard calibration reports.With built-in high-capacity local storage capable of storing over 100,000 raw data records, the device supports the retrieval and review of recorded data. Its tiered permission management mechanism ensures data security and traceability, perfectly integrating on-site constant-temperature sources with electrical measurement and data acquisition for verification. It is the preferred choice for on-site calibration of temperature sensors.

Selection Guide

ModelDTS-BGDTS-EMBGFunction
Wide-range
Temperature
Measurement
●●Ultra-wide temperature span from -40°C to 180°C. No medium change required across the entire range.
Intelligent Rapid
Cooling
●●Cools from 150°C to 25°C within just 30 minutes, ideal for fast thermal cycling tests.
Touch HMI●●Equipped with a 5-inch HD touchscreen and a graphical user interface for intuitive and easy operation.
Multi-Point Auto
Calibration
●●Supports multi-point self-correction mode; one-click start for automatic calibration process.
Intelligent
Program Setting
●●Multi-point temperature programming. Pre-store calibration points in the device; one-click sequential run, no repeated parameter entry.
Adjustable
Temperature
Control Rate
●●Features adjustable heating and cooling rates, allowing free setting of the heating and cooling rates.
Adaptive
Intelligent Temp
Control
●●Auto-tuning PID, auto parameter adjustment for varied loads & media.
Press-seal design●●Features a quick-press sealing structure for leak prevention and convenient on-site transport.
Overheat
Protection
●●Includes over-temperature protection and heating limit functions for safe and reliable operation.
Full-Category
Sensor Adaptation

●Independent standard channel; test channels for thermocouples, RTDs, transmitters and temperature switches.
Sensor
Management
Function

●Independent standard channel; test channels for thermocouples, RTDs, transmitters and temperature switches.
High-precision
Electrical Unit

●6½/7½ digit measurement modules as standard; electrical resolution ≥0.000001.
Automatic Data
Processing

●Auto conformity judgment; standard calibration result output.
Multi-channel
Automatic
Acquisition

●Automatically scans all channels; synchronously acquires temperature field and test data.
Full-Process
Real-Time
Monitoring

●Real-time display of electrical & temperature data, task progress, tolerance and deviation.
Data Storage &
Retrieval

●Built-in storage for 100,000+ calibration records; supports multi-condition combined search.
Permission
Management

●Hierarchical permission control; manages calibration, back-up/recovery & advanced configuration.

Technical Parameters

Measurement
Channel
Measuring RangeAccuracyResolution
SPRT
Measurement
0Ω to 400Ω±0.002Ω@(0 to 50)Ω ;
±40ppm RD @ (50 to 400)Ω
0.001mΩ
RTD
Measurement
0Ω to 400Ω±0.002Ω@(0 to 25)Ω ;
±80ppm RD @ (25 to 400)Ω
0.001mΩ
TC Measurement0mv to 100mv±(0.02% RD + 5μV)0.001uV
DCI
Measurement
0mA to 20mA±(0.02% RD + 2μA)1nA
DCV
Measurement
0V to 10V±(0.02%RD + 2mV)1uV
ModelDTS-EM20BGDTS-20BGDTS-EM30BGDTS-30BGDTS-EM40BGDTS-40BG
Electrical
Measurement
●
●
●

Temp.
Range
-20 ~ 180℃-30 ~ 180℃-40 ~ 180℃
Temp.
stability
0.02 ℃/10min (0 ℃)
Temp.
uniformity
≤0.02 ℃ (0 ℃) ; ≤0.01 ℃ (100 ℃)
Power1kW
Access opening ×
depth (mm)
φ80×250 (Supports customization)
Volume3L
Dimensions
(L×W×H)
225×430×475 (mm)
Working MediumL40N-180

Product Characteristics

Sensor Full Lifecycle
Management
     Comprehensive sensor management:add, delete, edit, view, and copy.
     Auto-loads formula coefficients for SPRT and RTC sensors based on model and range.
     Smart sensors: plug-and-play operation,automatic inventory tracking,and clear visual identification.
Module
Categories
Electrical Measurement Module 1
Supports
Standard
Type
Secondary SPRT(Pt25, Pt100)
 RTD, SMP, and other smart sensors
Supported DUT Types
Supports
Tested Type
RTDITS90 (Cu50, Cu100, Pt50, Pt100, PtX),
CVD, IEC60751, Nickel, SMP
RTCS, B, R
TCK, N, T, J, E, R, S, B, Wre3, Wre5
Transmitter
DCV, DCI
Temp. SwitchDry Contact


Integrated
Core
Hardware
Technology
Built-in
high-precision
electrical
measurement unit

Standard 6½-digit and 7½-digit modules (optional accuracy grade);

Measures resistance (Ω), DC voltage (DCV), and DC current (DCI);

Ultra-high resolution down to 0.1 μΩ, ideal for high-precision metrology tasks.

The temperature field and electrical measurement units are deeply integrated at both hardware and algorithmic levels.

4-Wire RTD
Constant-Current
Reversal
Measurement
Technology
Separates constant-current excitation from high-impedance voltage sensing circuits. Eliminates lead and contact resistance errors for exceptional measurement.
Cold Junction
Compensation
Design
Dedicated high-precision cold-junction sensor with multi-point monitoring and intelligent compensation, ensuring highly accurate thermocouple cold-junction measurements.
Automated
Calibration
Tasks
Indication
Calibration

Calibration Items: RTD, RTC, TC, DCV/DCI Transmitter, SWNTC, and other DUTs.

When paired with an electronic scanner switch, it enables fully automated multi-DUT calibration for temperature points, repeatability, and deviation—with unlimited temperature points. Raw measurement records are generated automatically.

Switching signal
Calibration

Supports temperature switches, oil-level/winding temperature controllers, and pressure-actuated thermometers. Supports simultaneous parallel verification of up to 6 channels. Automatically generates heating/cooling sequences to minimize stabilization time, and supports both ascending and descending ramp testing.

Task Configuration: Supports configuration of parameters such as ramp rate, temperature point intervals, accuracy class, and ascending/descending test parameters to complete the calibration point setup for switching signals.

Batch
Processing &
Customized
Automation
Workflows
Batch Import &
Auto-Calibration

Enables batch entry and editing of DUT serial numbers, with template-saving capability.

Supports configuration of temperature fluctuation, temperature deviation, and temperature change monitoring thresholds, used for automatic correction and pass/fail determination.

Multi-point self-calibration: Configure multiple temperature points at once and start the automated workflow with a single click.

Custom Test
Sequences
Supports programmable multi-point test sequences that automatically switch measurement modes to execute batch verification, calibration, comparison, and pass/fail determination—fully hands-free.
Intelligent Programmable
Multi-Temperature Segment
Verification Mode
Two operating modes available as needed:
Automatic programming mode: One-click setting of the full-process temperature sequence; the device executes automatically and sequentially.
Supports customized delayed start and stabilization hold time.
Multi-cycle configuration, automatic control stop upon task completion, unlimited number of temperature points, unattended completion of the entire test and verification process.
Manual programming mode: Import temperature sequences for automatic heating and stabilization, supports manual switching of temperature points as needed;
Simultaneously supports delayed start, cycle count, and shutdown settings, with an unlimited number of temperature points, facilitating on-site manual review and record comparison/marking.
Adaptive Smart
Temperature Control
Dynamically adapts gains to thermal load and medium changes. Selects the best strategy to ensure temperature uniformity and stability.
Multi-channel
Synchronous
Automatic
Acquisition
Once the temperature field stabilizes, the system automatically scans all channels in sequence and synchronously acquires data from both the temperature field and the DUT. It performs multiple ascending/descending readings as required by the regulations and automatically calculates the average, ensuring the objectivity and accuracy of the measurement data.
Regulation-Driven
Automated Data
Processing

Embeds calculation algorithms from national metrological verification regulations (e.g., JJG 229, JJG 141, JJG 351, JJG 630). Built-in intelligent stability algorithms continuously monitor the temperature change rate and automatically calculate key parameters—including indication error, hysteresis error, resistance, and temperature—eliminating manual computation.

Calibration items can be automatically matched with corresponding tolerance thresholds based on the instrument's accuracy class, outputting regulator-compliant calibration results.

Supports historical calibration record retrieval, allowing users to access raw data and full project configurations from any past record, with support for exporting raw data sheets.

Real-time
Monitoring
Throughout the
Process

Displays real-time, all-dimensional information including electrical measurement data, temperature field status, operating status, task progress, elapsed time, and stability countdown. In Indication Calibration mode, it simultaneously displays the current temperature point and the current calibration count.

Real-time deviation/tolerance calculation, with automatic highlighting of out-of-tolerance data.

Monitors the 10-minute fluctuation, maximum, and minimum values of both the standard and DUT channels in real time, with line charts provided for data visualization.

System
Management
& Data
Security
Access ControlSupports tiered access control across three categories: calibration operations, backup and restore, and advanced configuration. Fully compliant with metrology laboratory requirements.
Multiple Raw
Record Export
Options
Export via USB drive, QR code download, or other formats.
System LoggingComprehensive recording of all verification tasks, equipment operations, and fault/exception events. Automatic logging of operational data for remote diagnostics, enabling fast fault pinpointing and resolution.
Backup & Restore
Management

Restore from historical calibration records. Configurable retention period (up to 1+ year); default: 7 working days.

Supports data recovery at the individual calibration record level. Once the target record is retrieved, the system can restore the calibration configuration and data state to that specific point in time.

Resume After
Power Failure
Equipped with power-loss resume capability. In the event of a power failure, the system automatically resumes the calibration task, retaining previously measured data to prevent duplicate efforts.
Human-
Machine
Interaction
(HMI) &
Extensibility
Touchscreen
Human-Machine
Interface
5- or 7-inch HD touchscreen & graphical UI. Intuitive operation, minimal operator training.
Mass Data Storage
& Retrieval
8 GB built-in storage for 100,000+ calibration records. Advanced combined search (ID, date, project ID, instrument type, calibration date, etc.).
Communication
Interfaces
Standard interfaces: RS232/RS485, Wi-Fi, and LAN. Supports USB data export, ensuring long-term compliance and serviceability.
Sustainable
Upgrades
In-system upgrade via USB drive for the latest features and regulation revisions. Ensures long-term compliance and serviceability.
DTS-EM95BG Compact Smart Refrigerated Calibration Bath with Elec. Meas.
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:DTM-700G Blackbody Calibration Source (50℃ to 700℃)next:DTS-CT10G Smart Refrigerated Calibration Bath (-10℃ to 105℃)