Smart Dry Block Calibrator

DTG-EM1200G Smart Dry Block Calibrator with Elec. Meas.

2026-10-7 This article is read 153 Times

电测集成型-低温干体炉-1200.jpg

◇ Introduction ◇ Function◇ Parameter◇ Product order◇ Download◇ Related products

Introduction

The DTG-EM Smart Dry Block Calibrator with Elec. Meas. is a portable constant-temperature source for both high and low temperatures, offering high control accuracy, rapid temperature ramping and a uniform temperature distribution, making it suitable for on-site temperature calibration. The equipment features a built-in high-precision electrical measurement module, overcoming the limitations of traditional dry-block calibrators that are restricted to temperature control alone. It is capable of calibrating thermocouples, resistance temperature detectors and temperature transmitters, whilst simultaneously performing temperature control, signal acquisition, data processing and conformity assessment. It supports data storage and the generation of standard calibration reports, thereby achieving an integrated solution for temperature control, electrical measurement and data traceability, catering to both precision laboratory verification and on-site calibration scenarios.

Selection Guide

Function / ModelDTGDTG-EM
Touch HMIEquipped with a 5-inch HD touchscreen and a graphical user interface for intuitive and easy operation.●●
Multi-Point Auto CalibrationSupports multi-point self-correction mode one-click start for automatic calibration process.●●
Adaptive Intelligent Temp ControlAuto-tuning PID, auto parameter adjustment for varied loads & media.●●
Intelligent Program SettingMulti-point temperature programming. Pre-store calibration points in the device one-click sequential run, no repeated parameter entry.●●
Adjustable Temperature Control RateConfigurable multi-segment slope control. Auto heating/cooling and set point switching at preset rates, unattended operation.●●
Language and unitsThe system supports English and Chinese interfaces. Temperature units can be switched between Fahrenheit (°F), Celsius (°C), and Kelvin (K).●●
Communication InterfacesStandard interfaces: RS232/RS485, Wi-Fi, and LAN. Supports USB data export, ensuring long-term compliance and serviceability.●●
Full-Category Sensor AdaptationIndependent standard channel test channels for thermocouples, RTDs, transmitters and temperature switches.  ●
High-precision Electrical Unit6½/7½ digit measurement modules as standard electrical resolution ≥0.0000001. ●
Automatic Data ProcessingAuto conformity judgment standard calibration result output. ●
Multi-channel Automatic AcquisitionAutomatically scans all channels synchronously acquires temperature field and test data. ●
Full-Process Real-Time MonitoringReal-time display of electrical & temperature data, task progress, tolerance and deviation. ●
Permission ManagementHierarchical permission control manages calibration, backup/recovery & advanced configuration. ●
Data Storage & RetrievalBuilt-in storage for 100,000+ calibration records supports multi-condition combined search. ●

Technical Parameters


Measurement
Channel
Measuring RangeAccuracyResolution
SPRT
Measurement
0Ω to 400Ω±0.002Ω@(0 to 50)Ω,
±40ppm RD @ (50 to 400)Ω
0.001mΩ
RTD
Measurement
0Ω to 400Ω±0.002Ω@(0 to 25)Ω,
±80ppm RD @ (25 to 400)Ω
0.001mΩ
TC
Measurement
0mv to 100mv±(0.02% RD + 5μV)0.001uV
DCI
Measurement
0mA to 20mA±(0.02% RD + 2μA)1nA
DCV
Measurement
0V to 10V±(0.02%RD + 2mV)1uV
ModelDTG-
EMN30G
DTG-
EMN40G
DTG-
EMN42G
DTG-
EM660G
DTG-
EM1200G
Temperature
range (℃)
-30 to 150-40 to 150-42 to 15050 to 660300 to 1200
Accuracy±0.2℃±0.2℃±2℃
Stability±0.1℃±0.1℃±0.2℃
Axial
Uniformity
within 40mm
≤0.2℃≤0.15℃≤0.8℃
Hole depth150mm150mm135mm
Dimensions
(L×W×H)
(mm)
175×355×335175×295×350175×295×360
Hole sizes of
standard insert
Φ4.5mm, Φ6.5mm, Φ8mm, Φ10mmΦ6.5mm, Φ12mm
Specify the insertion depth and diameter of the sensors to be tested when placing an
order(Customization supported)
Power220V/50Hz; 110V/60Hz


Index numberMeasurement rangeAccuracy
SPRT-189~660℃0.0184℃@-200℃; 0.0198℃@0℃; 0.0204℃@100℃;
0.0211℃@200℃; 0.0237℃@300℃; 0.0389℃@600℃;
0.0422℃@660℃
RTD-200~850℃-0.0046℃@-200℃; -0.0119℃@-100℃; 0.0205℃@0℃;
0.0476℃@300℃; 0.0781℃@600℃
S/R-50~1768℃0.9228℃@0℃; 0.5959℃@300℃
0.5947℃@600℃; 0.5970℃@1000℃
B300~1820℃0.6510℃@1000℃; 0.6180℃@1200℃
0.6740℃@1800℃
K200~1372℃0.1933℃@300℃; 0.2395℃@600℃
0.3170℃@1000℃
N-200~1300℃0.1849℃@300℃; 0.2323℃@600℃
0.3250℃@1000℃
J-210~1200℃0.1432℃@300℃; 0.2050℃@600℃
0.2950℃@1000℃
E-200~1000℃0.1147℃@300℃; 0.1728℃@600℃
0.2860℃@1000℃
T-200~400℃0.2821℃@-200℃; 0.1222℃@400℃

Product Characteristics

Sensor
Management
Comprehensive sensor management:add, delete, edit, view, and copy.
Auto-loads formula coefficients for SPRT and RTC sensors based on model and range.
Smart sensors: plug-and-play operation,automatic inventory tracking,and clear visual identification.
DTG-EMN30G / DTG-EMN40G
DTG-EMN42G /DTG-EM660G
DTG-EM1200G
Reference
channel
Secondary SPRT (Pt25, Pt100)Standard Thermocouples: S, B, R
RTD, SMP and other smart sensorsIndustrial Thermocouples: T
Test channelTest typesSupported ModelsTest typesSupported Models
RTDITS90(Cu50, Cu100,Pt50, Pt100, PtX),
CVD, IEC60751,Nickel, SMP
RTCS, B, R
RTCS, B, RTCK, N, T, J, E, R, S, B, WRe3,
WRe5
TCK, N, T, J, E, R, S, B,
WRe3, WRe5
TransmitterDCV, DCI
TransmitterDCV, DCITemperature
Switch
SW
Temperature
Switch
SWCold Junction
Compensation
(CJC) Mode
Reference
channel
Internal CJC,
External CJC,
Manual Input
Spare NTCβ-Value, Steinhart,
Polynomial
Test
channel
Internal CJC,
External CJC,
Manual Input,
Scanner CJC
Basic
Parameters
Thermocouple channels support two cold-junction compensation modes:built-in compensation and manual input.
Electrical measurement channels support gain adjustment and zero-point calibration correction.
The electrical measurement filtering function can be switched on or off.
Thermocouple channels support one-touch "zero clearing"to eliminate systematic errors caused by zero drift.



Integrated
Core
Hardware
Technology
Built-in
high-precision
electrical
measurement unit

Standard 6½-digit and 7½-digit modules (optional accuracy grade);

Measures resistance (Ω), DC voltage (DCV), and DC current (DCI);

Ultra-high resolution down to 0.1 μΩ, ideal for high-precision metrology tasks.

The temperature field and electrical measurement units are deeply integrated at both hardware and algorithmic levels.

4-Wire RTD
Constant-Current
Reversal
Measurement
Technology
Separates constant-current excitation from high-impedance voltage sensing circuits. Eliminates lead and contact resistance errors for exceptional measurement.
Cold Junction
Compensation
Design
Dedicated high-precision cold-junction sensor with multi-point monitoring and intelligent compensation, ensuring highly accurate thermocouple cold-junction measurements.
Automated
Calibration
Tasks
Indication
Calibration

Calibration Items: RTD, RTC, TC, DCV/DCI Transmitter, SWNTC, and other DUTs.

When paired with an electronic scanner switch, it enables fully automated multi-DUT calibration for temperature points, repeatability, and deviation—with unlimited temperature points. Raw measurement records are generated automatically.

Switching signal
Calibration

Supports temperature switches, oil-level/winding temperature controllers, and pressure-actuated thermometers. Supports simultaneous parallel verification of up to 6 channels. Automatically generates heating/cooling sequences to minimize stabilization time, and supports both ascending and descending ramp testing.

Task Configuration: Supports configuration of parameters such as ramp rate, temperature point intervals, accuracy class, and ascending/descending test parameters to complete the calibration point setup for switching signals.

Batch
Processing &
Customized
Automation
Workflows
Batch Import &
Auto-Calibration

Enables batch entry and editing of DUT serial numbers, with template-saving capability.

Supports configuration of temperature fluctuation, temperature deviation, and temperature change monitoring thresholds, used for automatic correction and pass/fail determination.

Multi-point self-calibration: Configure multiple temperature points at once and start the automated workflow with a single click.

Custom Test
Sequences
Supports programmable multi-point test sequences that automatically switch measurement modes to execute batch verification, calibration, comparison, and pass/fail determination—fully hands-free.
Intelligent Programmable
Multi-Temperature Segment
Verification Mode
Two operating modes available as needed:
Automatic programming mode: One-click setting of the full-process temperature sequence; the device executes automatically and sequentially.
Supports customized delayed start and stabilization hold time.
Multi-cycle configuration, automatic control stop upon task completion, unlimited number of temperature points, unattended completion of the entire test and verification process.
Manual programming mode: Import temperature sequences for automatic heating and stabilization, supports manual switching of temperature points as needed;
Simultaneously supports delayed start, cycle count, and shutdown settings, with an unlimited number of temperature points, facilitating on-site manual review and record comparison/marking.
Adaptive Smart
Temperature Control
Dynamically adapts gains to thermal load and medium changes. Selects the best strategy to ensure temperature uniformity and stability.
Multi-channel
Synchronous
Automatic
Acquisition
Once the temperature field stabilizes, the system automatically scans all channels in sequence and synchronously acquires data from both the temperature field and the DUT. It performs multiple ascending/descending readings as required by the regulations and automatically calculates the average, ensuring the objectivity and accuracy of the measurement data.
Regulation-Driven
Automated Data
Processing

Embeds calculation algorithms from national metrological verification regulations (e.g., JJG 229, JJG 141, JJG 351, JJG 630). Built-in intelligent stability algorithms continuously monitor the temperature change rate and automatically calculate key parameters—including indication error, hysteresis error, resistance, and temperature—eliminating manual computation.

Calibration items can be automatically matched with corresponding tolerance thresholds based on the instrument's accuracy class, outputting regulator-compliant calibration results.

Supports historical calibration record retrieval, allowing users to access raw data and full project configurations from any past record, with support for exporting raw data sheets.

Real-time
Monitoring
Throughout the
Process

Displays real-time, all-dimensional information including electrical measurement data, temperature field status, operating status, task progress, elapsed time, and stability countdown. In Indication Calibration mode, it simultaneously displays the current temperature point and the current calibration count.

Real-time deviation/tolerance calculation, with automatic highlighting of out-of-tolerance data.

Monitors the 10-minute fluctuation, maximum, and minimum values of both the standard and DUT channels in real time, with line charts provided for data visualization.

System
Management
& Data
Security
Access ControlSupports tiered access control across three categories: calibration operations, backup and restore, and advanced configuration. Fully compliant with metrology laboratory requirements.
Multiple Raw
Record Export
Options
Export via USB drive, QR code download, or other formats.
System LoggingComprehensive recording of all verification tasks, equipment operations, and fault/exception events. Automatic logging of operational data for remote diagnostics, enabling fast fault pinpointing and resolution.
Backup & Restore
Management

Restore from historical calibration records. Configurable retention period (up to 1+ year); default: 7 working days.

Supports data recovery at the individual calibration record level. Once the target record is retrieved, the system can restore the calibration configuration and data state to that specific point in time.

Resume After
Power Failure
Equipped with power-loss resume capability. In the event of a power failure, the system automatically resumes the calibration task, retaining previously measured data to prevent duplicate efforts.
Human-
Machine
Interaction
(HMI) &
Extensibility
Touchscreen
Human-Machine
Interface
5- or 7-inch HD touchscreen & graphical UI. Intuitive operation, minimal operator training.
Mass Data Storage
& Retrieval
8 GB built-in storage for 100,000+ calibration records. Advanced combined search (ID, date, project ID, instrument type, calibration date, etc.).
Communication
Interfaces
Standard interfaces: RS232/RS485, Wi-Fi, and LAN. Supports USB data export, ensuring long-term compliance and serviceability.
Sustainable
Upgrades
In-system upgrade via USB drive for the latest features and regulation revisions. Ensures long-term compliance and serviceability.
DTG-EM1200G Smart Dry Block Calibrator with Elec. Meas.
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:DTG-EM660G Smart Dry Block Calibrator with Elec. Meas.next:DTS-CT10G Smart Refrigerated Calibration Bath (-10℃ to 105℃)

Copyright© Tai'an Dearto Automation Instrument Co., Ltd.

Chinese